실행을 하니까
아래와 같은 런타임 에러나 나네요..
NON-FATAL RUN-TIME ERROR: "hw03-01.c", line 330, col 13, thread id 0x00000D88: Function AI_VRead: (return value == -10401 [0xffffd75f]). unknownDeviceError: The specified device is not a National Instruments product, the driver does not support the device (for example, the driver was released before the device was supported), or the device has not been configured using the Measurement & Automation Explorer.
저 얘기가 제가 가지고 있는 DAQ(USB-6009)가 trational버전을 지원하지 않는 얘기 맞나요?
혹시 다른 드라이브 설치하고 라이브러리만 가져다 써도 되는건가요?
아니면 DAQmx버전에서
아날로그 입력 출력 담당하는 함수는 어떤건가요???
아래와 같은 런타임 에러나 나네요..
NON-FATAL RUN-TIME ERROR: "hw03-01.c", line 330, col 13, thread id 0x00000D88: Function AI_VRead: (return value == -10401 [0xffffd75f]). unknownDeviceError: The specified device is not a National Instruments product, the driver does not support the device (for example, the driver was released before the device was supported), or the device has not been configured using the Measurement & Automation Explorer.
저 얘기가 제가 가지고 있는 DAQ(USB-6009)가 trational버전을 지원하지 않는 얘기 맞나요?
혹시 다른 드라이브 설치하고 라이브러리만 가져다 써도 되는건가요?
아니면 DAQmx버전에서
아날로그 입력 출력 담당하는 함수는 어떤건가요???
허창원
허창원
예전에 개발하셨을 때는 Traditional NI-DAQ버전으로 개발하셨고,
이제는 DAQ 하드웨어가 바뀌었고, 그 하드웨어는 DAQmx를 지원하는 것같습니다.
AI_VRead() 같은 함수는 Traditional NI-DAQ 함수입니다. DAQmx 라이브러리를 이용하여 DAQ 부분을 새로 작성하셔야될 것 같습니다.
이제는 DAQ 하드웨어가 바뀌었고, 그 하드웨어는 DAQmx를 지원하는 것같습니다.
AI_VRead() 같은 함수는 Traditional NI-DAQ 함수입니다. DAQmx 라이브러리를 이용하여 DAQ 부분을 새로 작성하셔야될 것 같습니다.
매번 이렇게 답변 달아주셔서 감사합니다. 많은 도움이 되고 의지가 됩니다..^^;; 아직도 여쭈어볼게 많은데...
어렴풋이 추측하여 잘못된 코멘트를 드렸네요.
죄송합니다.